      17gw is about the same size as the Hiroshima bomb - 63 terajoules is 17 GWh and the 9GW data centre produces at least 16GWs of heat. Pretty scary when looked at like that.

      • humanspiral@lemmy.ca
        link
        fedilink
        English
        arrow-up
        4
        ·
        20 天前

        17gw of heat is both under and over estimate.

        3,600 of those industrial-scale generators to power Stratos

        Caterpillar 2.5mw generators have maximum efficiency of 45%, and so 19gw is peak thermal power. that is roughly 26 hiroshimas per day.

        It’s an over estimate because datacenter cpu/gpu capacity utilization is on average under 10%. It could still produce all that power for export to trap all that heat in a valley.

      • towerful@programming.dev
        link
        fedilink
        English
        arrow-up
        2
        ·
        20 天前

        Does “9GW data center” not mean “a data center that consumes 9GW of power”?
        Or is it “9GW of computers + 5GW of cooling + something”?

        • Pulsar@lemmy.world
          link
          fedilink
          English
          arrow-up
          4
          ·
          20 天前

          9GW should be the compute load goal, to which you need to add the mechanical and administrative loads. At higher scales they gain significant efficiencies which translates to market advantages.

          • FauxLiving@lemmy.world
            link
            fedilink
            English
            arrow-up
            1
            ·
            19 天前

            For comparison, a blast furnace making steel uses on the order of 3600 GWh/yr and the energy comes primarily from coal.

            9Gwh is a high number for a datacenter, but industrial processes use much more and much dirtier energy.

            That’s also one datacenter and the largest. Whereas there are many, many blast furnaces running all over the world.

            • humanspiral@lemmy.ca
              link
              fedilink
              English
              arrow-up
              1
              ·
              19 天前

              9gw if run 24/7 (capacity utilization is actually low on average in US) is 551.88 twh/year. 1500x. Natural gas is not that much cleaner than coal from co2/ghg warming perspective.

      • Pulsar@lemmy.world
        link
        fedilink
        English
        arrow-up
        2
        ·
        20 天前

        Not that it would matter for this conversation, but at hyperscalers levels, the energy required for mechanical loads is under 20% of the compute load. Wouldn’t surprise me if ~10% can be achieved at multi GW scale. Thus about 11GW total energy.